Fire Detection, And Fire Alarm Systems
FA1 SINGLE ZONE FIRE ALARM & EXTINGUISHER MONITOR MODULE
Compact, sealed, single zone, flush mount FA1 module 55 x 99 x 125 mm deep.
Incorporates effective audible & visual Fire Alarms, Fault Warnings & Remote Alarms.
Sealed, self contained module with touch switch controls for greater reliability.
System status display back illuminated by multi LEDs for easy to read, instant status recognition.
Easy to install, plug-in terminal on rear for Detectors, Extinguisher Release Alarm, Extinguisher Low Pressure Switch, Remote Alarms, & 2x 12 or 24 VDC power supplies.
FA2 TWO ZONE FIRE ALARM CONTROL MODULE
Compact, sealed, two zone, flush mount FA2 module 55 x 99x 125mm deep.
Incorporates effective audible and visual Fire Alarms, Fault Warnings & Remote Alarms.
Sealed, self contained module with touch switch controls for greater reliability.
System status display back illuminated by multi LEDs for easy to read, instant status recognition.
Easy to install, plug-in terminal on rear for 2 zones detectors, remote common zone alarms, and 12 or 24 VDC power supplies inputs.
FA3 THREE ZONE FIRE ALARM CONTROL MODULE
Compact, sealed surface mount FA3 PIM module 55 x 97 x 19 mm deep.
For mounting on dash or overhead console with no room behind for standard modules.
Incorporates effective audible and visual fire alarms, fault warnings & remote alarm.
Sealed, prewired module with touch switch controls for greater reliability.
System status display back illuminated by multi LEDs for easy to read, instant status recognition.
Separate under dash module with plug-in terminal for 3 zones of detectors, remote alarms, PIM dash display module and two 12 or 24 VDC power inputs.
FACEX FIRE ALARM & FIRE EXTINGUISHER CONTROL MODULE
Compact, sealed flush mount FACEX module 55 x 99 x 125 mm deep.
Incorporates effective audible and visual fire alarms, fault warnings & remote alarm.
Includes delayed extinguisher release with stop gas control & fault monitoring.
Sealed, self contained module with touch switch controls for greater reliability.
Easy to install, plug-in terminal on rear for detectors, extinguisher, break glass extinguisher release switch, remote alarm, and two 12 or 24 VDC power supply inputs.
FA4 FOUR ZONE FIRE ALARM CONTROL MODULE
Flush mount, four zone Fire Alarm control module 99 x 99 x 125 mm deep.
Four independent detection zones with audible and visual fire alarm warnings.
Four zones of fault monitoring with audible and visual fault warnings.
Sealed, self contained module with touch switch controls for greater reliability.
Easy to use LED back-lit system status display for instant status recognition.
Easy to install, self contained module with plug-in wiring terminals on rear for 4 zones.
Provision for dual 12 or 24 VDC power supplies of detectors, common alarms and 4 x zone alarm outputs.
Alarms
HIAVA REMOTE AUDIBLE & VISUAL ALARM UNITS
105 db audible alarm with an array of ultra bright flashing LEDs visual remote Fire Alarm unit.
Low current draw 350mA from DC supply 12 or 24 VDC.
Supplied with surface mount enclosure for engine room applications.
Overall dimensions 88 x 160 x 85 mm high
HIAVA Banshee – Fire Alarms
Fire Extinguisher Evacuate Area:- Australian Evacuation Tone- 500hz-1200hz sweeping 3.7 sec on, 0.25 sec off.
Shallow mounted base 120mm x 120mm x 60mm, overall height 130mm.
180 degree visual flash rate 1/sec.
Volume adjust -10db, -20db & max.
Fire Alarm Evacuate Area:- Australian Alert Tone- 420hz repeating 0.625 sec on, 0.625 sec off.
Shallow mounted base 120mm x 120mm x 60mm, overall height 130mm.
180 degree visual flash rate 1/sec.
Volume adjust -10db, -20db & max.